VOLUTE DUO™ thrives on dewatering sludge from plastic recycling
Plastic Recycling Plant, Netherlands
- VOLUTE DUO™ Dewatering Press
- Plastic production / Recycling
- DAF sludge
- Plastic Recycling Plant, Netherlands
From Zero Treatment to the Best Sludge Treatment Experience
Background
This plastic recycling factory was not dewatering their sludge at all, and they had to pay very high fees to evacuate it. The customer started looking into the different solutions available on the market but soon realized that the “hard-to-treat” nature of their sludge was not compatible with most technologies. AMCON’s sludge dewatering twin-screw press ended up being the only technology with the potential to treat their difficult sludge.
Installation Details
The plastic recycling factory decided to test a new setup for the treatment of their wastewater – a DAF unit followed by AMCON’s sludge dewatering twin screws screw press VOLUTE DUO™, designed to treat difficult abrasive and inorganic sludges. Seeing the results of this test – a very good filtrate quality and a high cake dryness of up to 49% without the use of any polymers in the dewatering step at all times and with no signs of blockage – it all persuaded the client to acquire a VOLUTE DUO™ unit two sizes bigger to keep up with their expanding production capacity.
- VOLUTE DUO
- Sludge Dewatering from Plastic Recycling
- Dewatered Sludge
Wastewater Treatment Plant Conditions and Performance Data
Model: | RVP-501 |
Sludge type: | DAF sludge from plastic recycling |
Total Solids (TS): | 9% |
Flow Rate: | 2.3 m3/h |
Throughput: | 207 kg-DS/h |
Cake DS Contents: | 49% |
SS Capture Rate: | 96% |